{"id":12415,"date":"2026-11-02T15:00:58","date_gmt":"2026-11-02T07:00:58","guid":{"rendered":"https:\/\/www.sxhtscti.com\/?post_type=product&#038;p=12415"},"modified":"2026-11-02T15:06:08","modified_gmt":"2026-11-02T07:06:08","slug":"mmo-marine-use-disc-anode","status":"publish","type":"product","link":"https:\/\/www.sxhtscti.com\/de\/produkt\/mmo-marine-use-disc-anode\/","title":{"rendered":"MMO Marine-use Disc Anode"},"content":{"rendered":"<p>MMO disc\u001etype anodes serve for cathodic protection of ship hulls, sluice gates and inner tank walls under fresh\u001ewater, brackish\u001ewater and seawater conditions.<\/p>\n<p>Technische Daten und Leistung<\/p>\n<table>\n<tbody>\n<tr>\n<td>Artikel<\/td>\n<td>Durchmesser (mm)<\/td>\n<td>Dicke (mm)<\/td>\n<td>Stromausgang (mA\/m)<\/td>\n<td>Nutzungsdauer (Jahre)<\/td>\n<\/tr>\n<tr>\n<td>Disc\u001etype Anode<\/td>\n<td>100<\/td>\n<td>2.0\u001e5.0<\/td>\n<td>20<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>270<\/td>\n<td>2.0\u001e5.0<\/td>\n<td>35<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>320<\/td>\n<td>2.0\u001e5.0<\/td>\n<td>49<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>458<\/td>\n<td>2.0\u001e5.0<\/td>\n<td>99<\/td>\n<td>20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>Sonderabmessungen auf Anfrage erh\u00e4ltlich.<\/p>\n<p>&nbsp;<\/p>\n<p>Coating system: Ruthenium\u001eIridium \/ Iridium\u001eTantalum Titanium substrate standard: ASTM B265 Gr1 titanium plate<\/p>\n<p>&nbsp;<\/p>\n<p>Chemische Zusammensetzung (Max. Gew.-%%)<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td>Fe<\/td>\n<td>C<\/td>\n<td>N<\/td>\n<td>H<\/td>\n<td>O<\/td>\n<td>Ti<\/td>\n<td>Sonstiges<\/td>\n<\/tr>\n<tr>\n<td>0.20%<\/td>\n<td>0.08%<\/td>\n<td>0.03%<\/td>\n<td>0.02%<\/td>\n<td>0.18%<\/td>\n<td>Gleichgewicht<\/td>\n<td>0.40%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>Beschleunigter Lebensdauerteststandard: NACE TM0108 2008<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td>Beschichtungssystem<\/td>\n<td>Medium<\/td>\n<td>Stromdichte (A\/m\u00b2)<\/td>\n<td>Temperatur (\u2103)<\/td>\n<\/tr>\n<tr>\n<td>Iridium Tantal<\/td>\n<td>1 mol\/L Na\u2082SO\u2084<\/td>\n<td>20000<\/td>\n<td>40\u00b15<\/td>\n<\/tr>\n<tr>\n<td>Ruthenium Iridium<\/td>\n<td>1 mol\/L H\u2082SO\u2084<\/td>\n<td>20000<\/td>\n<td>40\u00b15<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><b>MMO Mesh Anode for Concrete &amp; Bridge<\/b><\/strong><\/p>\n<p><strong><b> <img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-12418\" src=\"https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Mesh-Anode-for-Concrete-Bridge.png\" alt=\"\" width=\"340\" height=\"161\" srcset=\"https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Mesh-Anode-for-Concrete-Bridge.png 340w, https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Mesh-Anode-for-Concrete-Bridge-300x142.png 300w, https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Mesh-Anode-for-Concrete-Bridge-18x9.png 18w, https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Mesh-Anode-for-Concrete-Bridge-150x71.png 150w\" sizes=\"(max-width: 340px) 100vw, 340px\" \/> <img decoding=\"async\" class=\"alignnone size-full wp-image-12419\" src=\"https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Mesh-Anode-for-Concrete-Bridge2.png\" alt=\"\" width=\"237\" height=\"173\" srcset=\"https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Mesh-Anode-for-Concrete-Bridge2.png 237w, https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Mesh-Anode-for-Concrete-Bridge2-16x12.png 16w, https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Mesh-Anode-for-Concrete-Bridge2-150x109.png 150w\" sizes=\"(max-width: 237px) 100vw, 237px\" \/><\/b><\/strong><\/p>\n<p>MMO mesh anodes are applied for impressed\u001ecurrent cathodic protection of steel rebar in atmospheric\u001eexposed concrete. Used together with titanium<\/p>\n<p>conductive\u00a0tabs, expanded\u001emesh geometry guarantees uniform protective\u001ecurrent distribution.<\/p>\n<p>&nbsp;<\/p>\n<p>Technische Daten und Leistung<\/p>\n<table>\n<tbody>\n<tr>\n<td>Artikel<\/td>\n<td>Breite (mm)<\/td>\n<td>Dicke (mm)<\/td>\n<td>L\u00e4nge (m)<\/td>\n<td>Mesh Size(mm)<\/td>\n<td>Stromausgang (mA\/m)<\/td>\n<td>Nutzungsdauer (Jahre)<\/td>\n<\/tr>\n<tr>\n<td>Mesh\u001estrip Anode<\/td>\n<td>10<\/td>\n<td>0.6<\/td>\n<td>76<\/td>\n<td>2.5\u00d74.6<\/td>\n<td>1.32<\/td>\n<td>30\u001e100<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>13<\/td>\n<td>0.6<\/td>\n<td>76<\/td>\n<td>2.5\u00d74.6<\/td>\n<td>1.65<\/td>\n<td>30\u001e100<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>19<\/td>\n<td>0.6<\/td>\n<td>76<\/td>\n<td>2.5\u00d74.6<\/td>\n<td>2.42<\/td>\n<td>30\u001e100<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>25<\/td>\n<td>0.6<\/td>\n<td>76<\/td>\n<td>2.5\u00d74.6<\/td>\n<td>3.20<\/td>\n<td>30\u001e100<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>Coating system: Iridium\u001eTantalum coating Titanium substrate standard: ASTM B265 Gr1 titanium mesh<\/p>\n<p>Chemische Zusammensetzung (Max. Gew.-%%)<\/p>\n<table>\n<tbody>\n<tr>\n<td>Fe<\/td>\n<td>C<\/td>\n<td>N<\/td>\n<td>H<\/td>\n<td>O<\/td>\n<td>Ti<\/td>\n<td>Sonstiges<\/td>\n<\/tr>\n<tr>\n<td>0.20%<\/td>\n<td>0.08%<\/td>\n<td>0.03%<\/td>\n<td>0.02%<\/td>\n<td>0.18%<\/td>\n<td>Gleichgewicht<\/td>\n<td>0.40%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>Beschleunigter Lebensdauerteststandard: NACE TM0108 2008<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td>Beschichtungssystem<\/td>\n<td>Medium<\/td>\n<td>Stromdichte (A\/m\u00b2)<\/td>\n<td>Temperatur (\u2103)<\/td>\n<\/tr>\n<tr>\n<td>Iridium Tantal<\/td>\n<td>1 mol\/L Na\u2082SO\u2084<\/td>\n<td>20000<\/td>\n<td>40\u00b15<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong><b>MMO Rod Anode<\/b><\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-12420\" src=\"https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Rod-Anode.png\" alt=\"\" width=\"257\" height=\"224\" srcset=\"https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Rod-Anode.png 257w, https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Rod-Anode-14x12.png 14w, https:\/\/www.sxhtscti.com\/wp-content\/uploads\/2026\/11\/MMO-Rod-Anode-150x131.png 150w\" sizes=\"(max-width: 257px) 100vw, 257px\" \/><\/p>\n<p>MMO rod anodes form the core body of probe\u001etype anodes, used for impressed\u001ecurrent cathodic\u001eprotection systems for inner surfaces of pipelines, water tanks and pressure vessels.<\/p>\n<p>&nbsp;<\/p>\n<p>Technische Daten und Leistung<\/p>\n<table>\n<tbody>\n<tr>\n<td>Artikel<\/td>\n<td>Durchmesser (mm)<\/td>\n<td>L\u00e4nge (mm)<\/td>\n<td>Oberfl\u00e4che (m\u00b2)<\/td>\n<td>Stromausgang (mA\/m)<\/td>\n<td>Nutzungsdauer (Jahre)<\/td>\n<td>Anwendung<\/td>\n<\/tr>\n<tr>\n<td>Rod Anode<\/td>\n<td>12<\/td>\n<td>1000<\/td>\n<td>0.04<\/td>\n<td>6<\/td>\n<td>20<\/td>\n<td>Pipeline, water tank, pressure vessel<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>12<\/td>\n<td>1000<\/td>\n<td>0.04<\/td>\n<td>24<\/td>\n<td>20<\/td>\n<td>Pipeline, water tank, pressure vessel<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>20<\/td>\n<td>1000<\/td>\n<td>0.06<\/td>\n<td>36<\/td>\n<td>20<\/td>\n<td>Pipeline, water tank, pressure vessel<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>Sonderabmessungen auf Anfrage erh\u00e4ltlich.<\/p>\n<p>Beschichtungssystem: Ruthenium-Iridium \/ Iridium-Tantal-Titan-Substratstandard: ASTM B338 Gr1 Titanplatte<\/p>\n<p>&nbsp;<\/p>\n<p>Chemische Zusammensetzung (Max. Gew.-%%)<\/p>\n<table>\n<tbody>\n<tr>\n<td>Fe<\/td>\n<td>C<\/td>\n<td>N<\/td>\n<td>H<\/td>\n<td>O<\/td>\n<td>Ti<\/td>\n<td>Sonstiges<\/td>\n<\/tr>\n<tr>\n<td>0.20%<\/td>\n<td>0.08%<\/td>\n<td>0.03%<\/td>\n<td>0.02%<\/td>\n<td>0.18%<\/td>\n<td>Gleichgewicht<\/td>\n<td>0.40%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>Beschleunigter Lebensdauerteststandard: NACE TM0108 2008<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td>Beschichtungssystem<\/td>\n<td>Medium<\/td>\n<td>Stromdichte (A\/m\u00b2)<\/td>\n<td>Temperatur (\u2103)<\/td>\n<\/tr>\n<tr>\n<td>Iridium Tantal<\/td>\n<td>1 mol\/L Na\u2082SO\u2084<\/td>\n<td>20000<\/td>\n<td>40\u00b15<\/td>\n<\/tr>\n<tr>\n<td>Ruthenium Iridium<\/td>\n<td>1 mol\/L H\u2082SO\u2084<\/td>\n<td>20000<\/td>\n<td>40\u00b15<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>MMO disc\u001etype anodes serve for cathodic protection of ship hulls, sluice gates and inner tank walls under fresh\u001ewater, brackish\u001ewater and<\/p>","protected":false},"featured_media":12424,"template":"","meta":[],"product_brand":[],"product_cat":[18],"product_tag":[],"class_list":{"0":"post-12415","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-titanium-anode-for-cathodic-protection","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.sxhtscti.com\/de\/wp-json\/wp\/v2\/product\/12415","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sxhtscti.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.sxhtscti.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sxhtscti.com\/de\/wp-json\/wp\/v2\/media\/12424"}],"wp:attachment":[{"href":"https:\/\/www.sxhtscti.com\/de\/wp-json\/wp\/v2\/media?parent=12415"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.sxhtscti.com\/de\/wp-json\/wp\/v2\/product_brand?post=12415"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.sxhtscti.com\/de\/wp-json\/wp\/v2\/product_cat?post=12415"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.sxhtscti.com\/de\/wp-json\/wp\/v2\/product_tag?post=12415"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}